Materials Handling Equipment

Storax Ranger

Storax Ramada Ranger Shuttle launches in SA

Storax Ramada, our European principals, are market leaders with a versatile and successful shuttle system known as the Storax Ranger. As it is now tried and tested Ramada Storax have asked Barpro to market the Storax Ranger in South Africa. Barpro Storage has agreed to do so as the Storax Ranger is complementary to our range of mobile racking, which we’ve become so good at, having successfully implemented well over 200 systems in our more than 25 year history. Ranger shuttle has sold many thousands across Europe, and we are now incorporating this as an important addition to our product line-up as a locally available offering, and we expect our first SA orders/installations very shortly. Barpro Storage technicians will be trained in Europe on installation and maintenance, we will hold spares stock in SA, and we’ll be fully equipped to handle this exciting system quite soon. This system should receive serious consideration in any situation where drive-in might be considered – including forced cooling racks in the fruit industry – but also anywhere in an existing facility where greater capacity is needed (Shuttle is as space efficient as mobiles) but one doesn’t want to mess with an existing floor. Shuttle is, of course, often an integral part of many fully automated storage and retrieval systems (AS/RS), which we are also now able to offer through our European partners. Storax Ramada Ranger Case Study: Automated Barrel Storage [gravityform id=”8″ title=”true” description=”true”]

Storax Ramada Ranger Shuttle launches in SA Read More »

Would you like to reduce energy usage in your freezer store?

Reduce energy usage – I think the point is finally sinking in that freezer room doors are not your friends but an unfortunate necessity that need to be designed in such a way as to eliminate the ingress of moisture. Of course, doors aren’t the only route for moisture to gain access. Inferior insulated panel sealing will have the same effect as will access holes for light fittings and electrical cables which are not properly sealed. Pallets left for extended periods on warm loading docks will bring a surprising amount of moisture into the freezer. The moisture that gets through our defences makes its way to the coldest surface which is normally the evaporator fins. Any build-up of ice here reduces the heat that can be removed as part of the refrigeration cycle.   Your compressors can be going flat out, but with ice on the evaporators, their efficiency is significantly reduced. In those instances where the evaporators get turned off and the freezer door is left open, a fairly common occurrence when stock takes are in progress, the incoming moisture heads for the coldness of the floor. Even the smallest build-up of ice on mobile rails can cause the bases to slip, or worse still prevent them from moving at all.   When I joined the industry, freezer doors, protected if at all by half eaten plastic strip curtains, were left open all day. Indeed I suspect that refrigeration plants were designed on this basis. Slowly we were persuaded to close them by various means, none of which worked beyond the short term. Door keepers lost interest.   Motorised doors had a short life expectancy when faced with forklifts, those ever present weapons of mass destruction. Air curtains sounded good, but on a 5 metre high door the air volume, velocity and angle were rarely correct and they could end up encouraging moisture in rather than keeping it out.   Out of this confusion certain truths emerged. The number of freezer doors must be kept to a minimum and their size likewise. This led to additional doors designed to allow reach trucks in and out but which were otherwise kept closed. The main access door could then be significantly lower at say 2.5 metres to reduce moisture ingress. These worked even better when high speed doors were fitted. Unfortunately not enough design was sometimes put into the reach truck doors, where faulty seals could cause them to stick and allow for troublesome ice formation.   Another European development is the use of man on riders to move pallets from the freezer into the waiting trucks. This is now almost standard and allows access door heights to be further reduced. There are challenges, including how to position pallets on the forks so as not to break the bottom bearers when the front wheels are extended, and the angles between the airlock floor, dock leveler and truck floor. These can be resolved and have been at a local fruit packing operation.   Roll up doors are an Australian speciality. But they don’t like ice. If it builds up on the the roll up mat it becomes heavier and thicker which impedes operation. Hence they are always used with fans to keep them dry.   The use of pallet conveyors to move product in and out of freezer stores was a popular option in South Africa 20 years ago, faded from view and is now staging something of a comeback. Conveyors reduce door sizes to the minimum, just slightly bigger than the pallet, overcome any height differences between loading dock and freezer and provide a magazine effect which can balance the work rates in both areas. Pallets are stored at operating temperatures which reduces moisture build up. The interface between the conveyors and the doors needs to be properly designed and ice formation inside the hatches avoided. Capital costs can be a negative, but are normally justified if the savings from improved efficiencies are properly accounted for.                       Then dehumidifiers came along. While they can be energy intensive to run, if designed into airlocks or for loading platforms where the loading docks are properly sealed, and truck doors can be opened once the vehicle had docked, they work extremely well. I have been in one European freezer store where the success of the de-humidifiers and dock sealing caused an unexpected challenge, that of dust.  This is a problem I have yet to encounter in a South African freezer store.   The latest development is a combination of dehumidifier and high speed door. I saw an example working in a UK cold store some years ago but at that stage the pricing was prohibitive. Now there are some models on the local market which are proving very popular.                         Read more: What to consider when building a new cold or freezer store Read more: An insight to Montagues new cold store Read more: Improve your cold store’s efficiency

Would you like to reduce energy usage in your freezer store? Read More »

MAT Biddle Cold Store Air curtain Barpro Storage Storax Mobile Racking Storage solutions south africa (443x640)

FREEZER STORE ENTRANCES – How important are they?

A UK cold store owner remarked to me once that the electricity usage difference between a 30,000 and a 15,000 pallet freezer store was just over 1000 GBPs per year so long as the bigger store only had one commonly used access door. Having built both, he was in a position to know. The doors are just under 3 metres high and wider than the South African standard of 2.4 metres, with a demarcation line in the middle and entry on the left. Reach truck access is via a separate door. His freezer entrances have clear plastic flaps and an interior airlock with dehumidifier which exerts a positive air pressure. This keeps the cold air from escaping and the warm moist air from entering the store. There is no ice build-up or mist in the door way. Previously cheap electricity did not encourage South African operators to spend money on freezer doorways. In most there is a solid night door with a plastic strip curtain, some of which are broken or missing. The door may be motorised, but is too slow for high movement frequency and when the motorized system breaks it is seldom repaired. Doorways are frequently between 5 and 6 metres high and 2.4 metres wide to accommodate reach trucks. In some instances the door remains open all day with not even a strip curtain. At today’s electricity prices this is costing a fortune not only through the loss of expensive cold air but also the moisture in the warm incoming air ends up insulating the evaporator coils and making them inefficient. Multiple defrosts are expensive. Some door solutions to consider: Create a separate higher door for reach truck access and a lower one for product movement on motorised pallet jacks. Either create a small dehumidification airlock with positive pressure around the access door way or dehumidify the whole airlock. Install a high speed cloth door inside the freezer entrance and combine it with a dehumidifier. Install an insulated automated roll up door on the outside of the freezer. Install a fast opening 2 part door. Install an air curtain in lower doorways up to 4 metres. Consider the use of pallet conveyors for moving product into and out of freezers. Access can be a very expensive part of a cold store. It must be designed correctly but with the right equipment can reduce electricity bills significantly. Headline picture courtesy of MAT Biddle Cold Store Air (http://www.biddle.info/documents/UKbrochures/Invisidor%20MAT.UK.pdf)

FREEZER STORE ENTRANCES – How important are they? Read More »