Other Products

Febset 45

Do you have a hole in your cold store floor and not sure what to do?

Febset 45 is a specially formulated cement based product which provides a repair material for concrete slabs. Once applied the product reaches an adequate strength for trafficking, or other use, within an hour. Barpro has used Febset 45 for some years to fix damaged cold and freezer room floors. Advantages of Febset 45: High strength at a very early age (45 minutes) Minimum delay to traffic and production. Ready for use.  Only requires water (in exact amounts) High bond strength.  No secondary bonding agents required. Highly durable.  Excellent resistance to de-icing salts. High freeze / thaw resistance. No curing required. Non-shrink. Floors can be fixed at operational temperatures of -22° C   Typical Uses For use in concrete repair situation where the minimum delay and work disruption is of the utmost importance. Cold store floor and high traffic areas. Industrial floor areas, loading bays and warehouses. Around fixing bolts. Raising and leveling manhole covers, gratings, hydrants etc. For more information or to place your order contact us at info@barpro.co.za.  

Do you have a hole in your cold store floor and not sure what to do? Read More »

Rack Safety Inspections

In the last issue we talked about the sometimes disastrous, but fortunately uncommon, instance of rack collapse, and here we continue the discussion with further comment about the importance of damage inspections. We pointed out that a properly designed rack will only collapse if it is damaged or abused. It is an unfortunate fact of life that pallet racking in cold stores and warehouses is often subject to damage, usually by handling equipment, and this is true even with the best training and attitude on the part of operators. Modern racking is designed with built-in safety factors, and is usually able to sustain a certain amount of damage without seriously compromising its performance.   However, it must be understood that racking is invariably made from the lightest possible steel sections in order to maintain price competitiveness.   Accordingly it is vital that racking is regularly and systematically checked for damage, that this damage is formally reported and recorded, and that remedial action is effected immediately. The actual inspection can usually be tasked to a designated supervisor, but the responsibility rests with everyone from the Managing Director downwards. The inspector needs to be specifically trained for the job so that he has a clear understanding of what constitutes damage, the level of severity of such damage, and to what extent this presents danger to the overall integrity of the system. Pallet beams and frame uprights are the components most frequently damaged by forklifts, and these are the vital load-bearing elements of the system. Dents, twists, and deflections have clearly defined and measurable limits of acceptability, and the inspector has to systematically check for these damages, and to know how to measure and grade them for severity. ENQUIRE NOW The actual measuring of deflections, twisting, etc. can assist by means of a  Rack Inspection tool, which is available from Barpro at our Cape Town or Johannesburg offices. Damage grading is generally divided into colour-coded categories, whereby red is serious and requiring immediate remedial action (meaning, apart from anything else, completely unloading the affected rack without delay); orange is less serious and requires action, but without the same urgency; green covers issues that do not need urgent action but have to be noted, and monitored at next inspection. Recording the damage is by means of a check-list in chart format where each component is identified (beam, frame, connector, etc) according to exact location (rack number, bay number, level) to enable remedial action and ongoing control. These records should be centrally filed for immediate senior management access, and stored as history for future reference. How often should racking safety inspections be carried out? The simple answer is “as often as possible. In practice of course, one has to be realistic. The ideal situation is whereby each and every person working within the facility accepts that part of his job is to be aware of the potentials for danger and to report daily to his manager or supervisor anything that might be of consequence. This will include not only visible damage, but things like missing beam safety clips, poorly stacked pallet loads, careless or bad practices, etc. Once this ‘culture of awareness’ is firmly in place, it should be possible for the actual inspector to limit himself to a weekly walk-about visual check, and a formal inspection perhaps only monthly. Read more: Not all pallets can be safely stored on pallet racking Read more: Pallet Racking Beam Safety Clips Read more: Changing Load Parameters in Mobile Pallet Racking

Rack Safety Inspections Read More »

Southern Africa Frost Heave

Frost heave in Southern Africa – James Cunninghams’ response to “Freezing out Frost Heave in Tropical Climates”

 Southern Africa Frost Heave-  “I was interested to read your Cold Facts article on frost heave in tropical climates. I am involved with the installation and maintenance of Storax mobiles in Sub Saharan Africa. As Storax mobiles require a level floor we are particularly concerned about frost heave and have seen many examples of it. The climate in Southern Africa includes both tropical and subtropical areas. The Johannesburg area experiences nocturnal winter temperatures of below zero Celsius while Durban has high levels of humidity. Cape Town city temps do not go below zero Celsius. Originally the preferred method of preventing frost heave was to create air vents under the floor insulation. Frost heave was not really understood and stacking methods did not require particularly level floors. In one store the air vents were sealed to prevent rodent ingress. This led to frost heave in places of over 900mms. The adoption of mobile racking focused attention on level floors and frost heave in freezer stores. Initially there were incidents of floors “dropping” in mobile retrofit situations where a room was switched off to install the mobile rails in an overlay concrete slab. Heat from the curing slab melted 20 years of ice that had existed under the insulation. All new mobile rack equipped freezer stores in Southern Africa are designed to prevent frost heave. The most popular method is the electrical heater mat which comes on if the underfloor temperature reaches 4 degrees Celsius. There are generally three circuits laid in a protective sand bed. Problems tend to arise if the heater mats are turned off as any heave can cut the cables. I have seen one situation where heat mat cables were retrofitted under an existing floor via holes drilled in the existing underfloor insulation. In challenging ground conditions freezer stores can be elevated on columns. This is particularly advantageous in urban areas where the additional space can be used for parking cars! Floors can move by over 150mms relatively quickly where a heater mat has malfunctioned. All floor cracks should be investigated immediately. Use of a ball bearing can show how the floor is moving. More recently there have been frost heave problems in chilled fruit stores where temperatures are now able to go slightly below zero Celsius for extended periods. New stores are installing underfloor insulation and on occasion heater mats, especially if the floor is not elevated when compared to the surrounding area. Glycol mixtures heated via a heat exchanger from the condenser are becoming more common. Air pipes have also made something a comeback after experience gained from Australia where they are commonplace. However, as the original article noted, pipes need to be at a slight angle to allow condensation to drain and in humid areas should be accompanied by forced hot air via fans. I have seen an instance in Australia where ventilation pipes have been blocked by ice, resulting in heave. Glycol systems need to be watched. Flow meters are important as indicators that the glycol mixture is moving in any set of plastic pipes. Temperature is also important as the floor can be heated to unnecessary levels resulting in an increased heat load on the refrigeration system.” **To view the article “Freezing out Frost Heave in Tropical Climates“, written by Sheryl S Jackson, please visit **

Frost heave in Southern Africa – James Cunninghams’ response to “Freezing out Frost Heave in Tropical Climates” Read More »