Safety

DID YOU KNOW – Storax can withstand earthquakes !

In February 2010 an earthquake measuring 8.8 on the Richter scale hit Fruiticola Olmué, a fruit processing company in Chile, South America. Fruiticola had a Storax system installed holding over 2 300 pallets and remained unaffected. Following the tragic events, Fruiticola’s owner Max Hassler wrote to the then Managing Director of Storax – Ken Jones. He said: “I write to you in acknowledgement of the quality of the system installed in our plant in Chillan.  We had only very minor damage, a small purchase order is being made, and the system remained operational once we could get to it after the events here in Chile.  We are located less than one hundred kilometres from the epicentre of this very large quake.” Two years after the quake Fruiticola Olmué installed their 2nd Storax mobile system with a hold capacity of 7,850 pallets.  Storax mobiles installed in seismic areas have additional features which increase base stability. For the full story visit: http://warehousenews.co.uk/2012/03/storax-racking-systems-unshakeable/  

DID YOU KNOW – Storax can withstand earthquakes ! Read More »

Visit to Montagues New Cold Store at Truganina outside Melbourne, Australia

Montague Cold Storage has been in business for over sixty years. Family owned, Montague’s started life as a supplier of fruit and flowers before becoming one of the largest cold store operators in the states of Victoria and Tasmania with over 140,000 pallet spaces available. Phase 1 of Montague’s new Truganina store was commissioned at the end of 2014 and has a capacity of 30,000 pallet spaces. I was delighted to be shown around the facility by the Facilities Director, Glenn Edwards.   LOADING AREA                                                                                     LOADING DOCKS The loading docks at Truganina have been designed for maximum efficiency and in line with Health and Safety legislation. After entering the site through a special entrance, the trucks wait at a marshaling point until directed to a particular loading bay. Backing up to the loading bay is assisted by ground guides which make sure that the rear of the truck is correctly placed. Then the trailer’s rear protection bar is locked in position. Until the lock is in place, the internal loading bay door will not open nor can the dock leveler be activated. The lock prevents the truck from moving away from the loading dock with a forklift inside. The driver then enters vestibule of the loading dock through the door and opens the truck doors. The air seals activate to prevent the ingress of warm moist air, the dock leveler is put into position and the internal door opens. While waiting for the truck to be loaded/offloaded, the driver has access to bathroom facilities and a canteen. He is observed by the cold store staff as they must sign off that he is fit to drive the truck to its next destination. As his load is processed, the driver stands on an observation platform in the loading dock to check the pallets. When the doors are sealed and the paperwork completed, the lock is released and the truck leaves via a gate that only opens when the cold store staff have checked that everything is in order.                                                                                                                                                                               FREEZER ROOMS The freezer rooms are constructed from PIR panels. The local fire authority required that the freezer ceilings be fitted with sprinklers. Had the cold store been placed on the other side of the road, it would have fallen under another fire authority making sprinklers unnecessary. Hitting a sprinkler head will not in itself activate the system. Excessive heat must also be picked up by sensors. The freezer rooms are equipped with double deep racking. Case picking is an important aspect of the business and takes place inside the freezer. Product is supplied to the pick faces via roller beds. Stackers are not allowed in lanes where case picking takes place. Racked picking bays have been made wider than normal to allow for better access to the cases. Space has been created underneath the roller beds to allow room for the picker’s feet. The racking is of high quality and well protected. The upper levels have guides to assist with placing the pallets.                                                                                                                                                                     MATERIALS HANDLING EQUIPMENT Stackers with extendable forks are used to place and retrieve pallets in the double deep racking. Their front wheels must be able to go under the bottom level of pallets. Cases are picked via man on pallet movers. Stand on forklifts are used in the trucks. The stackers have no heated cabs and the fork lifts/pallet movers are all of the stand-up variety. High quality freezer clothing is worn by all cold store employees. The battery bay is well thought out including intelligent chargers which include automatic maintenance of battery water levels. The pallet movers have inbuilt printers and the scanners are attached to the machine with extendable restraints. Every machine has a driver control device, which limits who can drive what, and also sends information regarding impacts to the responsible manager.                                                                                   COLDSTORE CONSTRUCTION FEATURES Some cold store construction features are attached for interest.                                                                                                                                                                                                      

Visit to Montagues New Cold Store at Truganina outside Melbourne, Australia Read More »

The Importance of Heater Mats

Every freezer store must have some way of making sure that the ground temperature under the cold store floor does not approach 0⁰Celsius. While some South African cold stores achieve this by pumping heated water/glycol mix through plastic pipes in the subfloor, the common method is still to have an electrical heater mat.  This normally consists of three separate heater wires which are laid down in a sand bed under the polystyrene floor insulation.  The circuits come on if the under floor temperature gets to plus 4⁰C and stops the sub floor temperature from dropping further. If ice forms under a freezer it pushes up the wearing slab and could negatively affect the operation of the mobiles.  It is also very hard to reverse the process once there is ice under the floor.   As there have been several incidents recently of “frost heave” in South African freezer stores, we would advise all cold store managers to make sure they know where their heater mat control panel is located and to make sure that it is functioning correctly.       Read more: Have an ice problem? We have the solution… Read more: Newly built cold & freezer stores should be independently inspected Read more: Would you like to reduce energy usage in your freezer store?

The Importance of Heater Mats Read More »