cold store

What’s so different about cold store floors?

What’s so different about cold store floors?

Normal warehouse floors are designed to carry the loads that will be imposed on them, including forklifts, pallet racking systems or bulk product. These concrete floors are reinforced both to carry load and to stop unwanted cracking both during the curing process and thereafter for the life of the store. Storing new products should be done with care. I once visited a good friend whose office was on the third floor of an old CMT (cut, make and trim) building. All of a sudden his office door wouldn’t close. It didn’t take much investigation to reveal the cause. 12 pallets of sugar weighed rather more than fabric and were forcing the concrete floor downwards. All concrete floors will crack. However this process can be managed by way of fibre, reinforcing, anti-crack mesh, expansion/contraction joints and saw cut joints. If rails are installed in the concrete floor either for cranes or mobile racking, then increased reinforcing is likely both to assist in carrying and spreading the increased rail point loads and to prevent the concrete floor from cracking around the rails. This can happen as embedded rails are crack inducers. The actual design of normal concrete warehouse floors depends on the supporting ground beneath. If it is of a variable nature or not weight supporting, and the imposed loads will be relatively large, then piling may be needed. Freezer store concrete floors or wearing slabs must incorporate all the requirements of normal warehouse floors with a few extras for freezing. If the temperature of the subfloor approaches freezing, usually plus 4 degrees C is taken as the danger point, then any water moisture in the subfloor will freeze. When water becomes ice, it expands in volume and has to be accommodated. This normally leads to the concrete floor rising and cracking as the rise is variable over the floor area. Ice will lift just about any weight which is particularly important when pallet racking is present. As well as underfloor insulation, all freezer floors should have added protection from frost heave. In South Africa the current standard is the electric heater mat which is normally laid in three circuits in case there is a circuit malfunction. The mat only uses energy if the subfloor temperatures reaches 4 degrees or less. Some larger freezer stores are now using a warm piped glycol/water mixture which absorbs the waste heat given off by the condensers. These run continuously. The Australians favor underfloor 200mm diameter pipes through which warm air should be blown via a fan system. The pipes are laid at a slight angle to prevent moisture from lying in them as this might freeze, gradually closing the pipe. I was in one freezer where frost heave had raised portions of the floor by over 800mms. The store had a good underfloor air ventilation system but the openings had been blocked with checker plate to stop rats from entering. Mobile racking is especially affected by “frost heave” as the drive systems are designed to only operate on reasonably level floors. Freezer floors also experience a secondary contraction when cooled to below zero temperatures and it’s not unusual to see a 10 to 15mm gap between the concrete floor and the insulated wall panels. It is not a good idea to ‘cool’ a new freezer store quickly as it’s more likely to crack – especially around the door, a high traffic area. In freezer stores there can be either contraction or construction joints. I have seen freezer stores up to 1600m2 without contraction joints where the reinforcing is designed to make the floor shrink inwards. In this situation one would expect to have about 120 to 130 kgs of reinforcing per m3 of poured concrete. Contraction joints should be designed so that both sides of the joint can move, but that the same level is maintained. These should be armored when in high use areas like gangways. We try and design mobile layouts s that any contraction joints are under fixed racks. In such instances where a double fixed rack spans a joint, the one side should only be bolted down once the floor has stabilized at its sub- zero temperature. Although tempting in a mobile store, construction joints should not be placed at rails as this encourages cracking and voids. Cold store floors are the most important part of a freezer store and should be seen not just as a wearing surface but also as a foundation for the racking system. It is therefore worth taking time to get the floor right as subsequent repairs on a large scale at subzero temperatures are extremely difficult. For those who do have the occasional floor problem, Barpro stocks Spalpro 2000 and Febset 45. Read more: Issues to consider when building a new cold or freezer store Read more: New innovations at Novo Fruit Packers Read more: Would you like to reduce energy usage in your freezer store?

What’s so different about cold store floors? Read More »

Preventing fire in freezer stores

FX PREVENT – An alternative to sprinklers in colds stores and warehouses?

Sprinklers in cold and freezer rooms, whether they be ceiling mounted ESFR (Early suppression fast response) or in rack, are, as everyone knows, problematic. First there is the cost. If fire main pressures are considered too low, storage tanks, pumps and generators are required, which add significantly to project costs and not infrequently put projects on “hold”. ESFR sprinklers are of the dry pressurized variety, but each sprinkler head must penetrate the insulated ceiling. Improper sealing, especially with EPS panels, will cause water/ice saturation problems in the medium term. Sprinkler activations are far more likely to occur from accidental impacts than from fire. In a freezer store this turns the floor into a skating rink, stops the mobiles from moving and writes off stock. It can take days to remove the ice and get the store back into operation. In the unlikely event of a fire, even if the sprinklers control the blaze until the fire brigade arrives, the stock will still be written off either through temperature gain or smoke and water damage.   Precisely because sprinklers are so problematic in freezer stores, not to mention archives and museums, there has been a concerted European initiative to find better alternatives. One solution has been to pump gas into a freezer chamber as soon as smoke or heat is detected. One of these systems has been installed in Gauteng but the gas must be held on site in bottles which take up space. If there is a fire after several years system performance will depend on how well routine maintenance has been carried out.  Another option is to lower the oxygen content of the air inside the freezer chamber so that fires cannot start.     FX Prevent of Honselersdijkin in the Netherlands has been making LOX, or low oxygen systems for over 10 years. FX Prevent partners with Presscon which has been supplying nitrogen expansion systems for green house heating for over 20 years.  FX Prevent manufactures HP pressure swing absorption systems, which produce nitrogen efficiently for various sizes of building.     The nitrogen is mixed with the air in the cold chamber to reduce the oxygen content from 21.5% at sea level to approximately 17-16% (depending on the flammability of the goods stored in the room). At this level there is insufficient oxygen to allow a fire to start. The atmosphere in the cold room is similar to that experienced by the human body on a commercial aircraft so personnel can still breath normally. The EU is currently finalizing standards on their use and LOX systems have been successfully installed at many facilities including several owned by Kloosterboer.     In South Africa, LOX system costs would depend on exchange rates as well as the size of the freezer store. The number of doorways are critical and should be kept to a minimum. This is because the density of the air is slightly reduced through the process of replacing oxygen with nitrogen, and will suck normal air into the store when the door is open. The fitting of high speed doors to cold store entrances makes a significant difference (between 30 to 40%) to the capacity and cost of the LOX system required. For a Joburg freezer store of 15,510 m3 a FX prevent system with one entrance and high speed doors should cost between R3.0M and R3.5M to install.   While the type of insulation panel used is not critical, proper sealing of these panels definitely is, as the ingress of air via faulty panel joints will compromise the system design. Running costs must also be considered. On the store mentioned above, electricity costs should average 58,000 kWH per year. Maintenance would require 12 hours per year and could be done by trained local technicians. Replacement parts, mainly gaskets and filters, should not exceed R15 000 to R16 000 per annum.   While the running costs are not insignificant, at least the LOX system is in constant use. This is better than having a gas system to where you will only if it works  when you need it in an emergency.     There are no known LOX fire suppression systems operating in South Africa. However, they are becoming very popular in the larger European stores and the market is now taking off in China.   If anyone is interested in considering the approach of preventing cold store fires form ever starting in freezer chambers, they can either contact Barpro Storage or Arthur Ammerlaan at FX Prevent directly on arthur.ammerlaan@fx-prevent.com Read more: Why are these panels going up in flames?! Read more: Preventing fire in freezer stores Read more: Death of the sprinkler cartel

FX PREVENT – An alternative to sprinklers in colds stores and warehouses? Read More »

AJ - legends in cold storage

South African Cold Storage Legends

So who wants to marry a cold store manager who lives in the cold continuously?… (with apologies to the song I want to marry a lighthouse keeper) seriously, apart from those in the cold chain Industry, who knows how a cold store manager occupies his days? How many realize that without cold store managers, large conurbations could not exist? As long as their stores function and don’t burn down or let off ammonia gas, cold store managers are of little interest to the general public, when as guardians of our collective food supply, they definitely should be.   To rectify this social injustice, our newsletter intends to publish monthly profiles of such hardy individuals who have quietly managed our food supply for years in sub-zero conditions.   Ajay Kalan After completing a management course, doing rep work for a short period Ajay joined County Fair Chickens in Epping, Cape Town as a cold store receiving clerk back in 1991, and worked up the ranks. First as receiving clerk, invoice clerk, Department Head and then Cold Store Manager. His current position is that of Logistics Efficiencies Manager for the Astral Commercial Division. In this position Ajay has the added responsibilities of the Festive and Goldi facilities in Mpumalanga and Gauteng to ensure best practices are implemented and standardization is applied across warehouses. Ajay has taken part in the Astral Pinnacle studies which was started by Astral CEO MR Chris Schutte and successfully completed Potchefstroom University’s NQF 6 and 7 management qualifications. Ajay believes in setting standards and applying best practices to his operations, and, like all business leaders, is always up for a new challenge.   When he is not busy at work, Ajay enjoys spending quality time with his close knit and hugely supportive family. Ajay enjoys gardening and keeps both koi and marine reef fish.   If you know a cold store manager, who deserves similar recognition, please let Danielle at our Cape Town office know on 021 552 9190 or email her on danielle@barpro.co.za

South African Cold Storage Legends Read More »